SmartgridOne logo
SmartgridOne logo
AppCertifikat
Nya integrationerÖversikt
a-TroniXABB, FIMERABB, FIMERABB, FIMERABB, FIMERABB, FIMERABB, FIMERABB, FIMERABB, FIMERABB, FIMERABB, FIMERABB, FIMERABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV, hybrida och batteriomvandlareAPsystemsAteps Batteri
Autarco
BeauventC-BatteriCellpowerChisageDanfossDeltaDET Power PV, Hybrid och BatteriinverterDEYEDiehl-AkoDMEGC VäxelriktareDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP UtrustningESY-växelriktareFortona
FraxFroniusGoodWeGotionGrönare / Alfen
HiteHithium
Hypontech
All In One ESSHybrid Inverters
iWellJinkoKacoKehuaKostal
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRefurbRegitecRenonRitarSAJSchneider SunEzySchucoSCUSE2200H till SE6000HSessySigenergySinexcel
Socomec
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
SunwaytechSunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZeversolar
Installation
Kontrollera svarstidLicensNätverkRiktlinjer för ledningsdragning och anslutningSäkerhet, underhåll och juridiska meddelandenSnabbstartSpecifikationerStatus LED-lampor
Videohandledningar
EnheterPV hybrid and battery invertersHYXiPOWER
logotyp

Stödja enheter

Device TypeVariantsManualModbus TCP (Ethernet)RS485Curtailment
Hybrid växelriktareHYX-H5K-HTManual❌✅✅
HYX-H6K-HT
HYX-H8K-HT
HYX-H10K-HT
HYX-H12K-HT
HYX-H15K-HTManual
HYX-H20K-HT
HYX-H25K-HT

All In One ESS

Previous Page

iWell

Next Page

On this page

Stödja enheterKopplingRS485

Koppling

RS485

För RS485-koppling, använd den reserverade kommunikationsporten (N° 14) på växelriktaren.

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485 A (Pin 5)RS485 ARS485_POSRS485 ATX+
RS485 B (Pin 6)RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Varning
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.