SmartgridOne logo
SmartgridOne logo
Accessoires
App
Apparaten
Cloud
Energie Meter
EV Laadstation
Gasmeter
Geschakelde Belastingen
Ketel
Nieuwe integraties
Plc
Pv hybride- en batterijomvormers
a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV-, Hybride- en BatterijomvormersAPsystemsAteps Batterij
Autarco
BeauventC-BatterijCellpowerChisageDanfossDeltaDET Power PV-, Hybride- en BatterijomvormersDEYEDiehl-AkoDMEGC OmvormersDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP ApparatuurESY OmvormersEVEFortona
Foxess
FraxFroniusGoodWeGotionGroener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
iWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRegitecRenonRenoverenRitarSAJSchneider SunEzySchucoSCUSE2200H tot SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
HYD 3000…6000-ESPowerMagicTL-G3- en TLM/X-G3-serie
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Warmtepomp
Watermeter
Bedradings- en verbindingsrichtlijnenCertificaten
Configuratie van A tot Z
Controller
Externe Signaleringen
Gereedschapskist
Installatie
Klant specifiek
LicentieNetwerk
Probleemoplossing
Regeltijd reactieSnel aan de slagSpecificatiesStatus-LED'sVeiligheids-, onderhouds- en wettelijke mededelingenVideohandleidingen
ApparatenPv hybride- en batterijomvormersSofar
logo

Sofar HYD 3000…6000-ES Omvormers

Ondersteunde Apparaten

Image
Device TypeModbus TCP (Ethernet)RS485Curtailment
Sofar HYD 3000…6000-ES✅ (Solarman WiFi & ethernet dongles)✅❌

[!WAARSCHUWING]

  • Het wordt aanbevolen om RS485 te gebruiken, omdat de Solarman dongle mogelijk firmware wijzigt en de toegang tot Modbus TCP blokkeert!
  • Als u een Solarman dongle gebruikt, wordt aanbevolen om voor stabiliteit van de verbinding de ethernet dongle te gebruiken.

Bekabeling

Ethernet

Voor correcte ethernetbekabeling: volg de richtlijnen voor ethernetbekabeling.

Verbind de omvormer met uw internetnetwerk met behulp van de "Solarman dongle".

  1. Installeer de WiFi- of Ethernet-dongle in de omvormer en zorg dat deze verbonden is met uw netwerk.
  2. Noteer het serienummer van de dongle (zie de afbeelding links/boven). Dit heeft u nodig bij het instellen van de communicatie met de controller.

[!OPMERKING] Dongle firmware WiFi dongle firmware LSW3_15_FFFF_1.0.65 en ethernet dongle firmware ME_08_2701_2.06 zijn getest. Bij problemen kunt u proberen deze specifieke firmwareversies op de dongle te plaatsen. Neem hiervoor contact op met de leverancier van uw dongle.

Image

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485s TX+RS485 ARS485_POSRS485 ATX+
RS485s TX-RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image

Configuratie

Activeren van externe batterijsturing

Externe batterijsturing moet worden geactiveerd in het configuratiemenu van de omvormer via het LCD-display. In de instellingen van de omvormer:

  1. Ga naar "Basic settings".
  2. Ga naar "Energy Storage Mode"
  3. Stel dit in op “Set Passive Mode”
  4. Voor meer informatie, zie de Sofar HYD 3000/4000/5000/6000-ES Gebruikershandleiding pagina 26 en verder.

RS485

Waarschuwing
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.

Externe omvormersturing moet worden ingeschakeld in het configuratiemenu van de omvormer via het LCD-scherm.

  1. Druk kort op de knop naar beneden.
  2. U ziet "1. Enter settings", druk 2 seconden op de knop naar beneden om de instellingen te openen.
  3. Navigeer door de instellingen totdat u het volgende ziet:
    • Modbus Address of
    • Set ComProtocol
  4. Druk 2 seconden op de knop naar beneden om het adres in te stellen.
  5. Stel het adres in op de gewenste waarde.