SmartgridOne logo
SmartgridOne logo
Accessoires
App
Apparaten
Cloud
Energie Meter
EV Laadstation
Gasmeter
Geschakelde Belastingen
Ketel
Nieuwe integraties
Plc
Pv hybride- en batterijomvormers
a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV-, Hybride- en BatterijomvormersAPsystemsAteps Batterij
Autarco
BeauventC-BatterijCellpowerChisageDanfossDeltaDET Power PV-, Hybride- en BatterijomvormersDEYEDiehl-AkoDMEGC OmvormersDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP ApparatuurESY OmvormersEVEFortona
Foxess
FraxFroniusGoodWeGotionGroener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
iWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRegitecRenonRenoverenRitarSAJSchneider SunEzySchucoSCUSE2200H tot SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
HYD 3000…6000-ESPowerMagicTL-G3- en TLM/X-G3-serie
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Warmtepomp
Watermeter
Bedradings- en verbindingsrichtlijnenCertificaten
Configuratie van A tot Z
Controller
Externe Signaleringen
Gereedschapskist
Installatie
Klant specifiek
LicentieNetwerk
Probleemoplossing
Regeltijd reactieSnel aan de slagSpecificatiesStatus-LED'sVeiligheids-, onderhouds- en wettelijke mededelingenVideohandleidingen
ApparatenPv hybride- en batterijomvormersSofar

TODO: Het lijkt erop dat dit geldt voor meer omvormers?

logo

Sofar TL-G3 en TLM/X-G3 Serie Omvormers

Ondersteunde Apparaten

Device TypeModbus TCP (Ethernet)RS485Curtailment
...✅✅✅
Waarschuwing
Waarschuwing
  • De meeste apparaten kunnen communiceren via modbus TCP. Dit geldt niet voor de serie "SOFAR 1...40KTL"
  • Sommige omvormers vereisen specifieke firmware die beperkt is tot bepaalde distributeurs. Raadpleeg uw distributeur bij twijfel.
Image

Bekabeling

Ethernet

Verbind de omvormer met uw internetnetwerk via de "SOFAR SOLAR ETHERNET STICK LSE3".

Voor correcte ethernet bekabeling: Volg de richtlijnen voor ethernet bekabeling.

RS485

...TL-G3 & G1 & G2

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485s TR+RS485 ARS485_POSRS485 ATX+
RS485s TR-RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image

...TLX & TLM

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485s TR+ (pin 1)RS485 ARS485_POSRS485 ATX+
RS485s TR- (pin 3)RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image

Configuratie

RS485

Waarschuwing
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.

Externe omvormerbesturing moet geactiveerd worden in het configuratiemenu van de omvormer via het LCD-scherm.

  1. Druk kort op de onderstaande knop.
  2. U ziet "1. Enter settings", houd de knop 2 seconden ingedrukt om het instellingenmenu te openen.
  3. Navigeer door de instellingen tot u ziet:
    • Modbus Address of
    • Set ComProtocol
  4. Houd de knop 2 seconden ingedrukt om het adres in te stellen.
  5. Stel het adres in op de gewenste waarde.

PowerMagic