SmartgridOne logo
SmartgridOne logo
Accessories
AppCertificates
Configuration from A to Z
Control response timeController
Customer Specific
Devices
Boiler
Cloud
Energy Meter
ABBAccuenergyAcrelAlgodueAnexoBMR
Carlo Gavazzi
EM24EM111EM210EM300 SeriesEM500 SeriesEM511VMU-S Series
ChargeeChintCloud Meter DataDornscheidt
Eastron
Eniris
FluviusFroniusHagerHomeWizardHuaweiIneproIskra
Janitza
JoulzKaifaKamstrupLandis+GyrLegrandLitiotM-BusMetcomP1ApiPhoenix-ContactPilotSagemcom
Schneider
Self configured energy meterSeneca S604SessyShelly Energy metersSiemensSmappeeSmartgrid-readySocomecSolax
Solis
SunwodaTillquistVictronWeidmüllerYouLessZendure P1 MeterZiv
Ev Charging Station
Gas Meter
Heat Pump
New integrations
Plc
Pv Hybrid And Battery Inverters
Switched Loads
Water Meter
External Signals
InstallationLicenseNetworkQuick StartSafety, maintenance and legal noticesSpecificationsStatus LEDs
Toolbox
Troubleshooting
Video tutorialsWiring & connectivity guidelines
DevicesEnergy MeterCarlo Gavazzi

Carlo Gavazzi EM24 Energy Meter

logo

Supported Devices

Device TypeModbus TCP (Ethernet)RS485
Carlo Gavazzi EM24✅✅
Note
Note

The availability of ethernet and rs485 depends on the exact subtype of EM24 you use.

Image 1

Wiring

The SmartgridOne Controller and the device communicate via RS485 or Ethernet.

Ethernet

For correct ethernet wiring: Follow the the guidelines for ethernet wiring.

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
Terminal 41 / A-RS485 ARS485_POSRS485 ATX+
Terminal 42 / B+RS485 BRS485_NEGRS485 BTX-
Terminal 43 / GNDRS GNDGNDNot availableG
Image 1

Configuration

Check that the Carlo Gavazzi meter is set to read both import and export power. An unsuitable mode may lead to:

  • Missing readings of feed-in, or
  • Feed-in being counted as offtake (on top of the ‘actual offtake’)

You can set this in the ‘MEASurE’ configuration menu on the energy meter. This should be set to ‘b’.

Warning
Warning

This setting may not be present on MID certified models (model numbers ending in PFA and PFB).

Image 1
Warning
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.

Set the Modbus address through the power meter's “Address” configuration menu.

Carlo Gavazzi

Previous Page

EM111

Carlo Gavazzi EM111 Energy Meter

On this page

Supported DevicesWiringEthernetRS485Configuration