SmartgridOne logo
SmartgridOne logo
AppController
Externe Signale
Fehlerbehebung
Geräte
Boiler
Cloud
Energiezähler
EV-Ladestation
Gaszähler
Geschaltete Lasten
Neue Integrationen
Plc
PV-Hybrid- und Batterie-Wechselrichter
a-TroniXABB, FIMERADS-TecAforeAlphaESSAlpvoltAmpowrAngileAnklous PV-, Hybrid- und Batteriespeicher-WechselrichterAPsystemsAteps-Batterie
Autarco
BattlinkBeauventC-BatteryCellpowerChisageDanfossDeltaDET Power PV-, Hybrid- und Batteriespeicher-WechselrichterDEYEDiehl-AkoDMEGC-WechselrichterDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP EquipmentESY-WechselrichterEVEFairlandFortona
Foxess
FraxFroniusGoodWeGotionGreener / Alfen
Growatt
HiteHithiumHoymiles
Huawei
Hypontech
Hyxipower
iWellJinkoKacoKehuaKostal
Kstar
LibattionLONGiMarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerOX-PowerPixiiPower-SonicPoweroadPylontechRCT PowerRefurbRegitecRenonRitarSAJSavSchneider SunEzySchucoSCUSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunsynkSunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltTWSVaconVictronVolstoraWattsNextWeiheng
WHES
XantrexZendure SolarFlowZetaraZeversolar
Wärmepumpe
Wasserzähler
Installation
Konfiguration von A bis Z
Kundenspezifisch
LizenzNetzwerkRichtlinien für Verdrahtung und KonnektivitätSchnellstartSicherheits-, Wartungs- und rechtliche HinweiseSpezifikationenStatus-LEDsSteuerungsreaktionszeit
Toolbox
VideotutorialsZertifikate
Zubehör
GerätePV-Hybrid- und Batterie-Wechselrichter
Dysun Energy

Unterstützte Geräte

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
Hybrid inverterDysun Hybrid✅✅❌
FlexAmpFlexAmp One 3.6K, 5K, 8K, 10K, 12K❌✅

Verkabelung

Dysun Hybrid

Modbus TCP

  • Verbinden Sie den LAN-Port des Wechselrichters mit Ihrem lokalen Netzwerk.
  • Standardport: 502.
  • Die Modbus-Geräte-ID muss zwischen 1–247 eingestellt werden (Standard 1).

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485-ARS485 ARS485_POSRS485 ATX+
RS485-BRS485 BRS485_NEGRS485 BTX-
GNDRS GNDGNDNot availableG

Serielle Einstellungen:

ParameterWert
Baudrate9600 (Standard) oder wie im Wechselrichtermenü konfiguriert
Datenbits8
ParitätKeine
Stoppbits1

FlexAmp

Die FlexAmp-Serie kommuniziert ausschließlich über RS485.

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485-ARS485 ARS485_POSRS485 ATX+
RS485-BRS485 BRS485_NEGRS485 BTX-
GNDRS GNDGNDNot availableG

Serielle Einstellungen:

ParameterWert
Baudrate9600 (Standard)
Datenbits8
ParitätKeine
Stoppbits1

Konfiguration

Warnung
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.
  • Stellen Sie die Modbus-Adresse (Slave-ID) im Gerätemenü zwischen 1–247 ein.
  • Jedes Gerät am RS485-Bus muss über eine eindeutige Adresse verfügen.

FlexAmp-Einrichtung

Während der Gerätesuche oder manuellen Konfiguration werden Sie aufgefordert:

"Was ist in der Installation enthalten?"

OptionAuswahl, wenn
Solarmodule und Batterie (Standard)PV-Anlage und Batterie sind installiert
Nur SolarmoduleKeine Batterie vorhanden ist
Nur BatterieKeine PV-Anlage vorhanden ist

Wählen Sie die Option, die Ihrer Installation entspricht. Eine falsche Auswahl führt zu fehlenden oder falschen Messwerten.

Steuerung

Dysun Hybrid

Der Wechselrichter unterstützt die Batteriesteuerung:

  • Lademodus: Ladestrom in Ampere einstellen
  • Entlademodus: Entladeleistung als Prozentsatz der Nennleistung einstellen
  • Wenn die Smart-Grid-Steuerung deaktiviert ist, kehrt der Wechselrichter zum autonomen Betrieb zurück
Vorsicht
Vorsicht

Experimentell Die Steuerungsfunktionen für den Dysun Hybrid wurden nicht an Geräten im laufenden Betrieb validiert.


FlexAmp

Die FlexAmp-Serie unterstützt die PV-Abregelung — der Controller kann die maximale Solarproduktionsleistung in Echtzeit begrenzen.

  • Die Wirkleistungsbegrenzung wird als Prozentsatz der Nennleistung angegeben.
  • Wenn die Smart-Grid-Steuerung deaktiviert ist, verwendet das Gerät wieder seine konfigurierten lokalen Einstellungen (in der Regel unbegrenzte Ausgabe).
  • Die Abregelung gilt für die Gesamtproduktion aller angeschlossenen PV-Strings.
ModellNennleistungMaximale Auflösung der Abregelung
FlexAmp One 3.6K3 600 W1 W
FlexAmp One 5K5 000 W1 W
FlexAmp One 8k8 000 W1 W
FlexAmp One 10k10 000 W1 W
FlexAmp One 12k12 000 W1 W