ApparatenPV hybrid and battery invertersSMASolar
Ondersteunde Apparaten
| Device Type | Variants | Modbus TCP (Ethernet) | Curtailment | Minimum device firmware version |
|---|---|---|---|---|
| Sunny Tripower | Sunny Tripower 3.0 (STP3.0-3AV-40) | ✅ | ✅ | 04.03.07.R |
| Sunny Tripower 4.0 (STP4.0-3AV-40) | ||||
| Sunny Tripower 5.0 (STP5.0-3AV-40) | ||||
| Sunny Tripower 6.0 (STP6.0-3AV-40) | ||||
| Sunny Tripower 8.0 (STP8.0-3AV-40) | ||||
| Sunny Tripower 10.0 (STP10.0-3AV-40) | ||||
| Sunny Tripower X | Sunny Tripower X 12 (STP12-50) | 03.14.22.R | ||
| Sunny Tripower X 15 (STP15-50) | ||||
| Sunny Tripower X 20 (STP20-50) | ||||
| Sunny Tripower X 25 (STP X25) | ||||
| Sunny Tripower TL | Sunny Tripower 8000 TL-10 | 02.65.02.R | ||
| Sunny Tripower 10000 TL-10 | ||||
| Sunny Tripower 12000 TL-10 | ||||
| Sunny Tripower 15000 TL-10 | ||||
| Sunny Tripower 17000 TL-10 | ||||
| Sunny Tripower 5000 TL-20 | ||||
| Sunny Tripower 6000 TL-20 | ||||
| Sunny Tripower 7000 TL-20 | ||||
| Sunny Tripower 8000 TL-20 | ||||
| Sunny Tripower 9000 TL-20 | ||||
| Sunny Tripower 10000 TL-20 | ||||
| Sunny Tripower 11000 TL-20 | ||||
| Sunny Tripower 12000 TL-20 | ||||
| Sunny Tripower 15000 TL-30 | 02.90.01.R | |||
| Sunny Tripower 17000 TL-30 | ||||
| Sunny Tripower 20000 TL-30 | ||||
| Sunny Tripower 25000 TL-30 | ||||
| Sunny Tripower TLEE | Sunny Tripower 10000 TLEE-10 | 02.50.87.R | ||
| Sunny Tripower 15000 TLEE-10 | ||||
| Sunny Tripower 20000 TLEE-10 | ||||
| Sunny Tripower Core 1 | Sunny Tripower 50-40 | 4.01.05.R | ||
| Sunny Tripower 50-41 | ||||
| Sunny Tripower Core 2 | Sunny Tripower 110-60 | 1.01.04.R |
Bedrading
Voor correcte ethernet bedrading: Volg de richtlijnen voor ethernet bedrading.
Configuratie
- Verbind met uw computer op hetzelfde LAN-netwerk als de SMA Sunny Tripower.
- Surf in uw webbrowser naar het IP-adres van het apparaat.
- Log in als "Installateur."

- Ga naar het tabblad apparaatparameters.

- Klik op "Parameters bewerken."
- Open het dropdownmenu "Externe Communicatie" → "Modbus" → "TCP-server."
- Zet "Geactiveerd" op "Ja" en "Poort" op "502".
- Klik bovenaan de pagina op "Alles opslaan."