SmartgridOne logo
SmartgridOne logo
App
Nieuwe integratiesOverzicht
a-TroniXABB, FIMERABB, FIMERABB, FIMERABB, FIMERABB, FIMERABB, FIMERABB, FIMERABB, FIMERABB, FIMERABB, FIMERABB, FIMERABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV, Hybride en BatterijomvormersAPsystemsAteps batterij
Autarco
BeauventC-BatterijCellpowerChisageDanfossDeltaDET Power PV, Hybride en Accu OmvormersDEYEDiehl-AkoDMEGC OmvormersDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP ApparatuurESY OmvormersFortona
FraxFroniusGoodWeGotionGreener / Alfen
HiteHithium
Hypontech
All In One ESSHybrid Inverters
iWellJinkoKacoKehuaKostal
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRegitecRenonRenoverenRitarSAJSchneider SunEzySchucoSCUSessySigenergySinexcel
Socomec
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
SunwaytechSunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZeversolar
Bekabelings- en connectiviteitsrichtlijnenCertificaten
Controleer responsetijd
InstallatieLicentieNetwerkSnelle StartSpecificatiesStatus-LEDs
Veiligheid, onderhoud en juridische kennisgevingenVideo-instructies
ApparatenPV hybrid and battery invertersHYXiPOWER
logo

Ondersteunde Apparaten

Device TypeVariantsManualModbus TCP (Ethernet)RS485Curtailment
Alles-in-één ESSHYX-H6K-HTAManual❌✅✅
HYX-H9K-HTA
HYX-H12K-HTA
HYX-H15K-HTA

Bedrading

RS485

Voor RS485 bedrading, gebruik de COM-poort (N° 5) op de omvormer.

RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485 A (Pin 5)RS485 ARS485_POSRS485 ATX+
RS485 B (Pin 6)RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.

Hypontech