SmartgridOne logo
SmartgridOne logo
Accesorios
AplicaciónAvisos de seguridad, mantenimiento y legales
Caja de herramientas
Certificados
Configuración de la A a la Z
ControladorDirectrices de cableado y conectividad
Dispositivos
Bomba de Calor
Caldera
Cargas conmutable
Estación de Carga para Vehículos Eléctricos
Inversores Híbridos FV y de Batería
a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngularAPsystems
Autarco
Batería AtepsBeauventC-BateríaCellpowerChisajeDanfossDeltaDEYEDibujarDiehl-AkoDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEquipo EPEVEFortona
Foxess
FoxESS GMAXFoxESS Serie HFoxESS Serie R
FraxFroniusGoodWeGotionGreener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
Inversores DMEGCInversores ESYInversores Fotovoltaicos, Híbridos y de Batería AnklousInversores FV, Híbridos y de Batería DET PoweriWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRCT PowerReacondicionamientoRegitecRenonSAJSchneider SunEzySchucoSCUSE2200H a SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Medidor de agua
Medidor de Energía
Medidor de Gas
Nube
Nuevas integraciones
Plc
Especificaciones
Específico del Cliente
Inicio rápidoInstalaciónLEDs de estadoLicenciaRed
Resolución de problemas
Señales Externas
Tiempo de respuesta de controlTutoriales en video
DispositivosInversores Híbridos FV y de BateríaFoxess
logo

Dispositivos compatibles

Device TypeModbus TCP (Ethernet)RS485CurtailmentMinimum device firmware version
H3 (No Pro, No Smart): → ❗Ver nota más abajo ❗❌✅❗(ver abajo)Master: 2.05, Manager: 1.85 (*)
H3 AIO (Todo en uno)✅❌Master: 1.33, Manager: 1.37 (*)
H3-Smart⌛ (en desarrollo)Master: 1.25, Manager: 1.14 (*)
H3-ProMaster: 1.62, Manager: 1.34 (*)
H1(experimental, requiere pruebas)Master: 1.70, Manager: 1.78 (*)
H1-G2⌛ (en desarrollo)Master: 1.40, Manager: 1.54 (*)
P3-SH✅ (experimental)✅ (experimental)Master: 1.62, Manager: 1.34 (*)
Precaución
Precaución

H3 (No Pro, No Smart)

El H3 (No Pro, No Smart) tiene un protocolo de comunicación diferente dependiendo de la 'versión master' y 'versión manager' del inversor. Seleccione la integración correspondiente según las versiones de software del inversor.

✅ La reducción de potencia está soportada para las versiones de firmware master v.2.05 y manager v.1.85 y anteriores.

⌛ La reducción de potencia está en desarrollo para las versiones de firmware master v.2.06 y manager v.1.86 y superiores.

Advertencia
Advertencia

La serie H3 (no pro, no smart) utiliza un protocolo de comunicación diferente al de las series H3 Pro y H3 Smart. Por lo tanto, al seleccionar el tipo de dispositivo en el SmartgridOne Controller, debe estar muy seguro de seleccionar el tipo correcto.

Nota
Nota

Versiones de firmware soportadas

(*) La integración puede funcionar para versiones de firmware más antiguas, pero estas no han sido probadas.

Image 1

Cableado

Advertencia
Advertencia

La dirección modbus predeterminada, o ID del dispositivo, es 247. Tenga esto en cuenta al escanear un inversor. Puede cambiar las direcciones mínimas y máximas del bus que el controlador escaneará en los parámetros de búsqueda.

Ethernet

Para un cableado correcto de Ethernet: siga las .

Advertencia
Advertencia

No se puede conectar a través del dongle WiFi.

RS485

El inversor puede conectarse al SmartgridOne Controller mediante RS485. Esto se realiza a través de la conexión [J] en la imagen a continuación.

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
Logger 485A / pin 1RS485 ARS485_POSRS485 ATX+
Logger 485B / pin 2RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image 1

RS485 H3 Pro

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
EMS 485A / pin 17RS485 ARS485_POSRS485 ATX+
EMS 485B / pin 18RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image 1

Configuración para H3 (No Pro, No Smart) y H1-G2

1. Activación del monitoreo y gestión del inversor

El control debe activarse a través del inversor, y el medidor debe desactivarse. Esto se hace a través de la pantalla en el menú Feature Parm. Primero, abra el menú Feature Parm de la siguiente manera:

  1. Vaya al Menú.
Image 1
  1. Ingrese la contraseña. La predeterminada es 0000.
Image 1
  1. Seleccione Configuraciones.
Image 1
  1. Seleccione Feature Parm.

2. Activar control remoto

Utilice la pantalla más allá de la página Feature para activar el control, siguiendo los pasos a continuación:

  1. Seleccione Control remoto.
Image 1
  1. Colóquelo en Habilitar.
Image 1

3. Desactivar medidor

El medidor debe desactivarse. El control será tomado por el SmartgridOne Controller. Por lo tanto, el medidor no debe estar conectado al inversor sino al SmartgridOne Controller. Para desactivar el medidor en la configuración, siga estos pasos:

  1. Regrese a la página Feature.
  2. Seleccione Meter1.
Image 1
  1. Seleccione Establecer.
Image 1
  1. Colóquelo en Deshabilitar.
Image 1

4. Configuración de la dirección del inversor

La dirección del inversor también puede configurarse a través de la pantalla.

  1. Vaya al menú Configuraciones como se describió anteriormente.
  2. Seleccione Comunicación.
  3. Seleccione RS485.
  4. Seleccione ID del dispositivo.
  5. Configure el ID del dispositivo a la dirección deseada. Si conecta múltiples dispositivos al mismo bus RS485, debe asignar una dirección única a cada uno.
Image 1
Consejo
Consejo

Escaneo más rápido

El SmartgridOne Controller comienza a escanear desde la dirección 1 por defecto. Elegir una dirección más baja hará que su inversor sea encontrado más rápido.

Advertencia
Advertencia

Múltiples inversores

Si tiene múltiples inversores es importante configurar las direcciones paralelas, cada inversor debe tener una dirección diferente.

Configuración para H3-Smart y H3-Pro

El control remoto está activado por defecto, no es necesario cambiar ninguna configuración.

El cambio de la dirección del inversor (o ID del dispositivo) se puede hacer de la misma manera que en el H3 (ver arriba).

FoxESS GMAX

Previous Page

FoxESS Serie R

Next Page

On this page

Dispositivos compatiblesH3 (No Pro, No Smart)Versiones de firmware soportadasCableadoEthernetRS485RS485 H3 ProConfiguración para H3 (No Pro, No Smart) y H1-G21. Activación del monitoreo y gestión del inversor2. Activar control remoto3. Desactivar medidor4. Configuración de la dirección del inversorEscaneo más rápidoMúltiples inversoresConfiguración para H3-Smart y H3-Pro
directrices para el cableado Ethernet