SmartgridOne logo
SmartgridOne logo
Quick StartInstallationNetworkWiring & connectivity guidelinesApp
OverviewNew integrations
a-TroniXDaikin Altherma 3 HeatpumpsItho-DaalderopMyEnergi Heatpumps and BoilersNibeRemehaSmartgrid-readySmartgrid Ready ContactVaillant
SpecificationsStatus LEDsControl response timeVideo tutorialsCertificatesLicenseSafety, maintenance and legal notices
DevicesHeat pump
Remeha

Remeha Heatpump

Supported Devices

Device TypeModbus TCP (Ethernet)RS485
Remeha heatpump✅✅
Warning

Control is only possible using Boost or Block. Specific Wattage control is not supported!

Connection

The communication between the SmartgridOne Controller and the Remeha heatpump operates via RS485 or Modbus TCP..

RS485

RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
ARS485 ARS485_POSRS485 ATX+
BRS485 BRS485_NEGRS485 BTX-
GND (if available)RS GNDGNDNot availableG

Nibe

Previous Page

Smartgrid-ready

Next Page

On this page

Remeha HeatpumpSupported DevicesConnectionRS485