SmartgridOne logo
SmartgridOne logo
Acessórios
AplicativoAvisos de segurança, manutenção e legais
Caixa de Ferramentas
Certificados
Configuração de A a Z
ControladorDiretrizes para fiação e conectividade
Dispositivos
Bomba de Calor
Caldeira
Cargas Comutadas
Estação de Carregamento para Veículos Elétricos
Inversores Híbridos Fotovoltaicos e de Bateria
Medidor de Água
Medidor de Energia
ABBAccuenergyAcrelAlgodueAnexoBMR
Carlo Gavazzi
ChargeeChintDados do Medidor em NuvemDornscheidt
Eastron
Eniris
FluviusFroniusHagerHomeWizardHuaweiIneproIskra
Janitza
JoulzKaifaKamstrupLandis+GyrLegrandLitiotM-BusMedidor Zendure P1Medidores de energia ShellyMetcomP1ApiPhoenix-ContactPilotoPronto para rede inteligenteSagemcom
Schneider
ComPact NSXMasterPact MTZPM 3250PM 8000PowerTag EnergiaSérie IEM 2100Série IEM 2100Série IEM 3000Série PM 800Série PM 5000
Self configured energy meterSeneca S604SessySiemensSmappeeSocomecSolax
Solis
SunwodaTillquistVictronWeidmüllerYouLessZiv
Medidor de Gás
Novas integrações
Nuvem
Plc
Especificações
Específico para o Cliente
Início RápidoInstalaçãoLEDs de StatusLicençaRede
Resolução de Problemas
Sinais Externos
Tempo de resposta do controleTutoriais em vídeo
DispositivosMedidor de EnergiaSchneider

Medidores de Energia da Série PM 800 da Schneider-Electric

logo

Dispositivos Suportados

Device TypeModbus TCP (Ethernet)RS485
Schneider-Electric PM 820❌✅
Schneider-Electric PM 850
Schneider-Electric PM 870
Image 1

Fiação

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
D1/+RS485 ARS485_POSRS485 ATX+
D0/-RS485 BRS485_NEGRS485 BTX-
0VRS GNDGNDNot availableG
Image 1

Configuração

Aviso
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.

Consulte o manual do dispositivo para saber como acessar o menu de configuração do medidor de energia.