Autarco LD系列 RS485 接线
该页面描述了与Autarco LD系列混合逆变器通过Modbus-RTU (rs485) 的通信。 默认情况下,逆变器的地址设置为1。RS485接口是逆变器底部的一种4针连接器 在保护板后面。确切位置在下方图像的橙色框中标出:

仔细查看,端口看起来是这样的:

应使用适当的连接器将Autarco逆变器的这个4针连接器连接到SmartgridOne Controller。 在SmartgridOne Controller上,逆变器可以连接到RS485端口。接线如下:
RS485 Wiring
- For correct RS485 wiring: Follow the guidelines for RS485 wiring.
- If the wiring shown in the table below is incorrect, please let us know.
- There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
| Device | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB converter | RS485-Ethernet converter |
|---|---|---|---|---|
| Pin 3 | RS485 A | RS485_POS | RS485 A | TX+ |
| Pin 4 | RS485 B | RS485_NEG | RS485 B | TX- |
| N/A | RS GND | GND | Not available | G |
NOTE: RS485 Device Addresses
- You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
- Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
- For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.